UTRAN uses the measurement control message to
inform the UE what events need to
trigger measurement reporting. All intra-frequency measurement report events
are identified with 1X.
Event
1A: A primary pilot channel enters the reporting range
If the
network, in the measurement report mechanism field, requires the UE to report
event 1A while the UE has entered the Cell_DCH state, then when a primary pilot
channel enters the reporting range, the UE will send a measurement report.
In order to reduce the signaling traffic flow
of the measurement report, the TIME-TO-TRIGGER parameter is used so that the UE
will not trigger measurement reporting before the primary pilot enters the
reporting range and is maintained for a certain period of time. This parameter
is also used in other events. An example of measurement reporting triggered by event
1A is given below:
Generally, if event 1A is triggered, the UE
will send a measurement report to UTRAN, and UTRAN will deliver an ACTIVE SET
UPDATE signaling message to update the active set. However, UTRAN may give no
response after the UE sends the measurement report (for example, due to
insufficient capacity). In this case, the UE will shift from event reporting to
periodic reporting mechanism, and the content of the measurement report includes
the information of the cells in the active set and the cells in the monitored
set that has entered the reporting range. The UE will not stop sending
periodically the measurement report until this cell is successfully added into
the active set or leaves the reporting range, as shown below:
Event
1B: A primary pilot channel leaves the reporting
range
If several cells satisfy the reporting
condition simultaneously after the trigger delay, the UE will sort the cells
according to the measurement values and report all the measurement results.
Event
1C: The primary pilot channel in a non active set is better than the primary
pilot channel in an active set
This event can be
described through the following example:
In this
example, the cells where P CPICH 1, P CPICH 2 and P CPICH 3 are belong to an
active set, while that of P CPICH 4 does not. This event is used to replace the
poor cells in the active set, if the number of cells in the active set reaches
or exceeds active set replacement threshold.
Event
1D: The best cell changes
In order to prevent frequent triggering of
event 1D due to signal fluctuations when the channel difference is small, which
results in unnecessary increase of the air interface signaling traffic flow, we
can use the hysteresis parameter, as shown below:
As we can see, as the hysteresis condition is
not met at the second time, event 1D reporting is not triggered. This parameter
can also be used in other events.
Event
1E: The measurement value of a primary pilot channel exceeds the absolute
threshold
Event 1E can be used to trigger the measurement
reports of cells including those detected by the UE before it receives the
adjacent cell list.
Event
1F: The measurement value of a primary pilot channel is lower than the absolute
threshold
PLUR
Putri Touor,,si Smith Delvis
Putri Touor,,si Smith Delvis
Tidak ada komentar:
Posting Komentar